Cookie Consent by TermsFeed.com
NTE Logo
NTE Logo Mobile
Worldwide supplier of high quality electrical / electronic components
Call Us: +800-631-1250

Worldwide supplier of high quality electrical / electronic components

Call Us: +800-631-1250
ISO logo

Circuit Protection

Radial Lead Thermal Cutoff

Radial Lead Thermal Cutoff

The TCO (Thermal Cut−Off) responds to temperature by interrupting an electrical circuit when the operating and/or environmental temperature exceeds the thermal rating of the device. NTE’s radial lead TCO2 accomplish this when the internal fusible alloy is melted by reaching the temperature of the melting point of the alloy, forming two separate balls at the edges of the leads by surface tension of the alloy to permanently open the circuit.

Axial−lead TCO devices presently predominate over radial−lead devices. This results, at least in part, from design difficulties that exist in manufacturing a reliable, inexpensive radial−lead TCO device. However, in many circuit applications radial−lead devices are preferable since they take up a smaller area on a printed circuit board. Their compact size enables ease of assembly into the smallest of transformers ensuring total thermal protection

Features:

  • Non-Resettable
  • Maximum Rating: 5 Amps, 250 Volts
  • Typical Operating Temperature Tolerance +1−2°C
  • Full 2 3/4” leads to fit all replacement configurations
  • All types meet UL E214712 and VDC−40017057
  • RoHS Compliant

pdf icon download Data Sheet

NTE Type No. Functioning Temperature Holding Temperature Maximum Temperature
°C °F °C °F °C °F
8000 76 168 53 127 200 392
8005 86 187 61 142 200 392
8010 102 216 77 171 200 392
8015 115 239 89 192 200 392
8020 130 266 103 217 200 392
8025 136 277 111 232 200 392
8030 145 293 118 244 200 392
8035 150 302 123 253 200 392